Coriolis Mass Mass Flowmeter Calibration cov txheej txheem
Tso lus
Coriolis Mass Flowmeters ncaj qha ntsuas cov dej ntws loj raws li lub zog coriolis. Lawv muab cov raug siab (± 0.1% -0.2%), teb sai (<100ms), and strong stability. They are widely used in high-precision applications such as the chemical industry (e.g., measuring corrosive media) and the petroleum industry (crude oil trade settlement). Before calibration, confirm the instrument model (e.g., CMF100 series), range (0-50 t/h), and other parameters. Also, check the installation conditions (straight pipe length required: ≥10D) and the appearance of the instrument.
Thaum lub sijhawm ntsuas tshuaj, siv qhov nruab nrab zoo sib xws rau qhov kev ua haujlwm tiag tiag (piv txwv li, kev hloov cov roj crude), tswj qhov kub hloov pauv (± 1 degree) thiab siab hloov (<0.1 MPa), and strictly follow JJG1030-2020 regulations. During data processing, key metrics such as basic error (≤±0.15%) and repeatability (≤0.05%) must be calculated. If the results fail to meet the standards, investigate for sensor zero drift or signal processor failure.